Product Parameter
Optical characteristic parameter table |
||||||
optical characteristics |
test condition |
least value |
representative value |
crest value |
unit |
|
work pattern |
Continuous / modulation |
|||||
polarization |
stochastic |
|||||
MFMC-20000 |
100% power with a continuous output |
|
20000 |
|
W |
|
MFMC-30000 |
100% power with a continuous output |
|
30000 |
|
W |
|
Power regulation range |
|
10 |
|
100 |
% |
|
The central wavelength |
100% Continuous |
1070 |
1080 |
1090 |
nm |
|
Spectral Bandwidth (3dB) |
100% Continuous |
|
5 |
8 |
nm |
|
Short-time power stability |
And 100% continuously for> 1h |
|
±1 |
±2 |
% |
|
Long-time power stability |
100% continuously for> 24h |
|
±2 |
±3 |
% |
|
Beam mass (BPP) |
Output fiber core diameter is 100um |
3.2 |
|
4.2 |
mm x mrad |
|
Output fiber core diameter is 120um |
4.5 |
|
6 |
|||
Output fiber core diameter is 200um |
8 |
|
10 |
|||
Laser turn on time |
|
|
150 |
200 |
μs |
|
Laser closure time |
|
|
150 |
200 |
μs |
|
modulating frequency |
100% output |
|
|
|
KHz |
|
Indicate red light power |
|
400 |
|
|
uW |
|
Fiber cable length |
|
|
20 |
|
m |
|
Output fiber core diameter |
100 (150 / 200 customizable) |
μm |
||||
Fiber-optic cable bending radius |
|
200 |
|
|
mm |
|
Output method |
LOE |
|
||||
General feature parameters |
||||||
general characteristic |
test condition |
least value |
representative value |
crest value |
unit |
|
working voltage |
|
360 |
400 |
440 |
VAC |
|
interiorinput power |
MFMC-20000100% output |
|
|
62 |
KW |
|
MFMC-30000100% output |
|
|
93 |
|||
operating ambient temperature |
|
10 |
25 |
40 |
℃ |
|
Relative humidity of the working environment |
|
10 |
|
80 |
% |
|
cooling-down method |
hydrocooling |
|||||
cooling medium |
Distilled water (above 0℃) / ethylene glycol antifreeze (below 0℃) |
|||||
Storage temperature |
|
10 |
25 |
60 |
℃ |
|
Machine size |
750*1100*1070(W*D*H) |
mm |
||||
The weight of the machine |
MFMC-20000 |
478(±10) |
kg |
|||
MFMC-30000 |
590(±10) |
|||||
Laser is under water-cooled conditions |
||||||
order number |
characteristic |
parameter |
unit |
|||
1 |
cooling-down method |
hydrocooling |
|
|||
2 |
water temperature |
Winter 20 |
Summer 24 |
℃ |
||
3 |
water gage |
≥4.5 |
bar |
|||
4 |
MFMC-20000 Water flow requirements |
≥160 |
L/min |
|||
MFMC-30000 Water flow requirements |
≥250 |
|||||
5 |
Rated cooling capacity of MFMC-20000 chiller |
≥40 |
KW |
|||
Rated cooling capacity of MFMC-30000 chiller |
≥60 |